PXI System Setup and Maintenance

The PXI System Setup and Maintenance course is an introduction to NI PXI hardware. It explores the components of PXI systems and illustrates how to safely connect, set up, troubleshoot, and maintain the hardware.

Jump to Lesson List

Duration

  • 10 lessons | 1.5 hours

Audience

  • System technicians and/or operators who are responsible for setup, maintenance, and troubleshooting of PXI systems.

Course Objectives

  • Safely and effectively set up and configure a PXI system.
  • Safely insert and remove peripheral modules into compatible PXI chassis slots.
  • Follow procedures for safe system operation, including ensuring proper airflow to the system and safely powering the system on and off.
  • Identify and test hardware connections using NI MAX.
  • Follow routine maintenance procedures to ensure safe and reliable system performance.
  • Apply basic troubleshooting techniques to determine which part of the system is causing unexpected results.

Prerequisites

  • Basic computer and hardware knowledge

Hardware and Software

NI Online Training courses are best utilized on systems meeting minimum requirements for best performance. Use the following guidelines:

Software

  • NI MAX
  • InstrumentStudio

Hardware

Use simulated hardware where applicable or the list below as a reference if you want to program and test the hardware-related exercises:

  • PXIe-1092
  • PXIe-1082
  • PXIe-1065
  • PXIe-5122
  • PXIe-5644R
  • PXIe-8840
  • PXIe-8398
  • PXIe-8399
  • PXIe-4139
  • PXIe-5622
  • PXI-6251
  • PXI-5105
  • PXI-6683


    Milestone
    • Lesson List


      Introducing PXI

      Required
      Lesson
      | Duration: 7 minutes
      Overview of the PXI system and comparing modular instruments.
      View Details

      Comparing PXI and PXIe

      Required
      Lesson
      | Duration: 7 minutes
      Compare the PXI and PXIe chassis.​
      View Details

      Matching PXI Slots and Modules

      Required
      Lesson
      | Duration: 8 minutes
      Match the modules with appropriate slots in the PXI chassis.
      View Details

      Inserting and Removing a Module

      Required
      Lesson
      | Duration: 7 minutes
      Explore the steps for inserting and removing the modules properly.
      View Details

      Setting Up a PXI System

      Required
      Lesson
      | Duration: 11 minutes
      Explore how to connect and power PXI systems with an embedded or MXI controller.
      View Details

      Exploring NI MAX

      Required
      Lesson
      | Duration: 9 minutes
      Use NI Measurement & Automation Explorer to view and configure hardware and software․
      View Details

      Ensuring Proper Airflow

      Required
      Lesson
      | Duration: 4 minutes
      Ensure a proper airflow in the chassis.
      View Details

      Managing Hardware Calibration

      Required
      Lesson
      | Duration: 7 minutes
      Perform self-calibration, locate calibration information, and identify when external calibration is required for PXI modules.
      View Details

      Troubleshooting and Replacing PXI Parts

      Required
      Lesson
      | Duration: 8 minutes
      Learn how to identify issues that may occur in a PXI system and take steps to resolve them.
      View Details

      Calculating PXI Power Requirements​

      Required
      Lesson
      | Duration: 12 minutes
      Calculate power consumption and select the appropriate hardware for a system.​